DIN 54837 Chamber | DIN 5510-2 Tests

DIN 54837 Chamber

Compliance

DIN 54837, DIN 5510-2


The DIN 54837 Chamber, in accordance with DIN 54837/DIN 5510, is designed to determine the burning characteristics of railway material exposed to a wide opening gas burner flame, including damage range, smoke development, and droplet test.  

DIN 5510-2 uses DIN 54837 test results for materials classification.

DIN 54837 Chamber in SGS

DIN 5510-2 Flammbility Classes S2 to S5

Classification S2 S3 S4 S5
Length Destroyed ≤30cm ≤25cm ≤20cm ≤0cm
Afterflame Time No Requirement ≤100s ≤10s ≤0s

DIN 5510-2 Smoke Generation Classes

Classification Criteria
SR1 Not Achieved >100(%*min)
SR1 ≤100(%*min)
SR2 ≤50(%*min)

DIN 5510-2 Droplet Formation Classes

Classification Criteria
ST1 Droplet
ST2 No Droplet

DIN 54837 Chamber consists of

  • Stainless steel test chamber, with an internal size of 1350mm x 800mm x 800mm.

  • The test chamber is equipped with 2 observation glass windows on the front which is complied with DIN 50050-2.

  • Stainless steel square grille at the bottom of the test chamber for ventilation, grille size 30 by 30mm, height 30mm.

  • Anemometer, measurement range up to 10 m/s, with a resolution of 0.1 m/s.

  • Smoke measurement device, complies with DIN 50055, the light source is 2900K lamp.

  • Temperature measurement device, used to measure the exhaust duct temperature, 3 K type insulated thermocouples, measurement range up to 300 degrees.

  • Timing device, used to record the burning time, afterglow time, droplet time etc.

  • Wide opening burner, installed on the sliding rail which is easy to apply the flame to the specimen.

  • Calibration device, stainless steel plate with 3 thermocouples on the rear, measuring range up to 900 degrees, used to calibrate the burner.

  • Stainless steel specimen holder and support stand.

  • Data acquisition system, used to record the smoke measurement data.

  • Operation software, English Windows based.