Full Face Masks Flammability Tester
Compliance
EN 136
The Full Face Mask Flammability Tester, in accordance with EN 136 Clause 8.5 Flammability, is designed to assess the flammability performance of a full face mask exposed to a defined single flame source or six-point flame source.
EN 136 defines three classes of flame flammability performance for full face mask products.
Class 1, where the mask needs to pass a single flame source impact resistance test, and leaktightness test.
Class 2, where the mask is required to pass a six-point flame source impact test, and leaktightness test.
Class 3, where the mask has to pass the six-point flame source impact test, the resistance to thermal radiation test, and leaktightness s test.
The Full Face Mask Flammability Tester can conduct the single flame source and multi-point flame source test.
During the flammability test, the full face mask is mounted on a dummy head which can be rotated at a linear speed of 60mm/s. A single point flame is applied directly below the mask for 5 seconds. If the mask does not ignite or the flame is extinguished within 5 seconds, the mask passes the test.
In the multi-point flame test, the mask is mounted on the dummy head, the multi-point flame is applied to the mask for 5 seconds. After the applied flame is removed, if the mask does not ignite or the flame is extinguished within 5 seconds, the full face mask passes the test.
Before and after these tests, the full face mask shall meet the requirement of the leaktighness test.
Features
The full face mask flammability tester consists of a test bench, metallic dummy & rotation device, burner & gas supply device.
Compact steel test bench, with black coating for long-life use.
Equips with a metallic dummy head mounted on the bench stand, the stand can rotate in a horizontal circle at the liner speed of 60mm/s.
Equips with six TEKLU burners, the height of burners are individually adjustable.
The propane gas supply to each burner is adjustable.
Two flame modes are available and can be rapidly exchanged.
Provides flame calibration device, working range up to 1200 degrees.