ENV 1187 Roofing Test

ENV 1187 Roofing Test 3

Compliance

ENV 1187 Test 3, ISO 12468, EN 13501-5


The ENV 1187 Roofing Test 3 Device is designed to determine the performance of roofing materials exposed to external radiant heat sources and flame.

ENV 1187 describes four test methods:

ENV 1187 Test 1 With burning brands.
ENV 1187 Test 2 With burning brands and wind.
ENV 1187 Test 3 with burning brands, wind and supplementary radiant heat.
ENV 1187 Test 4 With two stages incorporating burning brands, wind and supplementary radiant heat.

And, the tests listed above are independent and not substitutable with each other.

  • Test 1, 2, 3 assess the flame spread across the external surface of the roof.

  • Test 1, 3, 4 assess the penetration of the flame and the generation of burning molten droplets.

  • Test 2, 3 are not applicable to geometrically irregular roofing materials or roof-mounted equipment such as ventilation units and roof lights.

  • The test stand is made of welded metal tube, which is coated with black painting for long life use.

  • The test stand position can be adjusted by the pneumatic cylinder.

  • The angle of the test stand can be adjusted from 0 to 50 degrees, which meets the requirements of ISO 12468 and ENV 1187.

  • The duct is made of stainless steel and with grilles in the duct and outlet.

  • The duct can be automatically adjusted the angle from 0 to 35 degrees.

  • With a blower to provide airflow up to 250m3/min.

  • With an anemometer to measure the airflow, with an accuracy of 0.1m/s.

  • The radiant panel dimension is 600mm by 600mm, can provide the radiant heat up to 15 kW/m2.

  • Provide a heat flux meter to measure the radiant heat flux.

  • Provide pilot flame burner, and gas control unit.

  • Provide a control cabinet, with the gas control device, control unit, and display meters.

Features:

 

MOTIS offers all EN 1187 tests device, contact us for more details.